  features n shrink tubing protected winding n fixed lead spacing n high saturation current up to 10 a n inductance range: 1 h to 100 mh n rohs compliant* applications n dc/dc converters n power supplies n output chokes n emi/rfi flters rlb0913 series radial lead inductor inductance test frequency voltage 1-6.8 h ........................ 7.96 mhz/1 v 10-100,000 h .................... 1 khz/1 v operating temperature ................................ -55 c to +125 c (temperature rise included) storage temperature ..... -55 c to +125 c temperature rise .... 40 c at rated i rms rated current ........... inductance drops 10 % at i sat electrical specifcations @ 25 c general specifcations core .............................................. ferrite wire ............................ enameled copper terminal finish ........................ cu/ag/sn tubing ........... shrink tube 125 c, 600 v packaging .................... 200 pcs. per tray materials product dimensions dimensions: mm (inches) *rohs compliant *rohs compliant & aec-q200 qualified *rohs compliant aec approved (select models) lead free *rohs compliant versions available lead free versions are rohs compliant* bourns part number inductance q min. q test freq. (mhz) srf min. (mhz) dcr typ. (w) dcr max. (w) i rms typ. (a) i sat typ. (a) ** k- factor l (h) tol. (%) rlb0913-1r0k 1 10 20 7.96 150 0.009 0.013 7.45 10 189.0 rlb0913-1r5k 1.5 10 20 7.96 130 0.013 0.016 5.75 8.5 159.9 rlb0913-2r2k 2.2 10 20 7.96 100 0.014 0.021 5.6 6.5 122.3 rlb0913-3r3k 3.3 10 20 7.96 79 0.02 0.025 4.6 5.5 99.0 rlb0913-4r7k 4.7 10 20 7.96 51 0.02 0.03 4 4.3 83.2 rlb0913-6r8k 6.8 10 20 7.96 29 0.025 0.035 3.65 3.7 67.1 RLB0913-100K 10 10 50 2.52 14 0.036 0.045 3.1 3 59.4 rlb0913-120k 12 10 50 2.52 13 0.038 0.05 2.9 2.7 53.3 rlb0913-150k 15 10 40 2.52 12 0.043 0.056 2.8 2.3 48.3 rlb0913-180k 18 10 40 2.52 11 0.048 0.061 2.6 2.2 42.4 rlb0913-220k 22 10 40 2.52 9.2 0.053 0.07 2.55 2 39.2 rlb0913-270k 27 10 30 2.52 8.5 0.061 0.08 2.5 1.7 35.2 rlb0913-330k 33 10 30 2.52 7.8 0.070 0.09 2.45 1.6 31.0 rlb0913-390k 39 10 30 2.52 6.9 0.076 0.1 2.4 1.5 29.3 rlb0913-470k 47 10 30 2.52 6.5 0.107 0.16 2.35 1.4 26.3 rlb0913-560k 56 10 30 2.52 5.4 0.12 0.18 1.75 1.3 23.9 rlb0913-680k 68 10 30 2.52 4.9 0.169 0.21 1.4 1.2 21.9 rlb0913-820k 82 10 30 2.52 4.1 0.189 0.23 1.35 1.1 19.8 rlb0913-101k 100 10 20 0.796 3.7 0.219 0.28 1.2 0.91 18.1 rlb0913-121k 120 10 20 0.796 3.4 0.266 0.32 1.05 0.84 16.4 rlb0913-151k 150 10 20 0.796 3.2 0.305 0.37 1 0.75 14.7 rlb0913-181k 180 10 20 0.796 2.8 0.399 0.58 0.75 0.69 13.4 rlb0913-221k 220 10 20 0.796 2.7 0.453 0.65 0.7 0.64 12.2 rlb0913-271k 270 10 20 0.796 2.4 0.627 0.75 0.6 0.57 11.0 rlb0913-331k 330 10 20 0.796 2.3 0.719 0.85 0.56 0.54 9.9 rlb0913-391k 390 10 20 0.796 2.1 0.899 1 0.5 0.48 9.2 rlb0913-471k 470 10 20 0.796 1.9 1.018 1.1 0.47 0.46 8.3 rlb0913-561k 560 10 20 0.796 1.8 1.136 1.4 0.45 0.41 7.6 rlb0913-681k 680 10 20 0.796 1.6 1.272 1.6 0.42 0.38 6.8 rlb0913-821k 820 10 20 0.796 1.5 1.702 1.8 0.41 0.35 6.3 rlb0913-102k 1000 10 50 0.252 1.3 2.35 2.9 0.35 0.29 5.7 rlb0913-122k 1200 10 50 0.252 1.1 2.672 4 0.3 0.13 5.2 rlb0913-152k 1500 10 20 0.252 1 3.626 6.1 0.285 0.08 4.7 rlb0913-182k 1800 10 20 0.252 1 4.063 6.4 0.27 0.08 4.2 rlb0913-222k 2200 10 20 0.252 0.9 4.600 6.8 0.245 0.08 3.8 rlb0913-272k 2700 10 20 0.252 0.9 5.251 7.7 0.23 0.08 3.4 rlb0913-332k 3300 10 20 0.252 0.7 7.478 9 0.195 0.08 3.1 rlb0913-392k 3900 10 20 0.252 0.6 8.287 14 0.185 0.08 2.9 electrical schematic typical part marking 102 inductance code: - first two digits are signifcant - third digit represents the number of zeroes to follow ~ continued on next page ~ **k-factor: to calculate core fux density, bp-p (gauss) = k x l(h) x d i (peak-to-peak ripple current, a), determine core loss from core loss vs. flux density plot. max. dia. 5.00 1.0 (.197 .039) 5.00 0.5 (.197 .020) 8.50 (.335) 0.65 0.1 (.026 .004) 212 12.50 (.492) max. * rohs directive 2002/95/ec jan. 27, 2003 including annex and rohs recast 2011/65/eu june 8, 2011. specifcations are subject to change without notice. the device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. users should verify actual device performance in their specifc applications.
specifcations are subject to change without notice. the device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. users should verify actual device performance in their specifc applications. rlb0913 series radial lead inductor electrical specifcations @ 25 c (continued) bourns part number inductance q min. q test freq. (mhz) srf min. (mhz) dcr typ. (w) dcr max. (w) i rms typ. (a) i sat typ. (a) ** k- factor l (h) tol. (%) rlb0913-472k 4700 10 20 0.252 0.5 9.244 16 0.175 0.05 2.6 rlb0913-562k 5600 10 20 0.252 0.4 13.38 18 0.145 0.05 2.4 rlb0913-682k 6800 10 20 0.252 0.4 15.18 19 0.135 0.05 2.2 rlb0913-822k 8200 10 20 0.252 0.3 17.10 21 0.13 0.05 2.0 rlb0913-103k 10,000 10 40 0.0796 0.3 19.59 25 0.12 0.05 1.8 rlb0913-123k 12,000 10 40 0.0796 0.3 22.03 33 0.115 0.04 1.6 rlb0913-153k 15,000 10 40 0.0796 0.2 30.47 37 0.1 0.04 1.5 rlb0913-183k 18,000 10 30 0.0796 0.2 34.38 40 0.09 0.04 1.3 rlb0913-223k 22,000 10 30 0.0796 0.1 45.6 56 0.08 0.03 1.2 rlb0913-273k 27,000 10 30 0.0796 0.1 52.26 62 0.075 0.03 1.1 rlb0913-333k 33,000 10 30 0.0796 0.1 59.8 70 0.07 0.03 1.0 rlb0913-393k 39,000 10 30 0.0796 0.1 67.81 80 0.065 0.03 0.9 rlb0913-473k 47,000 10 20 0.0796 0.1 88.83 99 0.055 0.03 0.8 rlb0913-563k 56,000 10 20 0.0796 0.1 100.3 135 0.05 0.02 0.7 rlb0913-683k 68,000 10 20 0.0796 0.1 141.9 150 0.045 0.02 0.7 rlb0913-823k 82,000 10 20 0.0796 0.1 183.7 212 0.04 0.02 0.6 rlb0913-104k 100,000 10 20 0.0252 0.1 210.1 235 0.04 0.02 0.6 **k-factor: to calculate core fux density, bp-p (gauss) = k x l(h) x d i (peak-to-peak ripple current, a), determine core loss from core loss s. flu ensity plot. how to order rlb0913 - 102 k model value code (see table) tolerance code k = 10 % core loss vs. flux density 1 10 100 1000 10000 100 10 1000 10000 core loss (mw) flux density (gauss) 50 khz 100 khz 200 khz 300 khz 500 khz 600 khz 1 mhz 01/17 asia-pacifc: tel: +886-2 2562-4117 email: asiacus@bourns.com europe: tel: +36 88 520 390 email: eurocus@bourns.com the americas: tel: +1-951 781-5500 email: americus@bourns.com www.bourns.com


▲Up To Search▲   

 
Price & Availability of RLB0913-100K

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X